Showing results: 151 - 165 of 169 items found.
-
40-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-005 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-192-012 -
Pickering Interfaces Ltd.
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
M9135A -
Keysight Technologies
The M9135A is a general purpose switch with 20 independent, single-pole, single-throw (Form A) switches in a single PXI module. This module is ideal for switching heavy loads or power supplies including voltages mains or DC current. The heavy-duty armature relays are rated for up to 5A and 300W, enough for inductive or capacitive loads. Choose from the heavy-duty power connector or an unterminated power cable.
-
M9132A -
Keysight Technologies
The M9132A is a high-density, general purpose switch with50 independent, single-pole, single-throw (Form A) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights or actuate external power relays and solenoids. The high-speed, long-life reed relays can handle 100Vrms and 1A, with up to 25W power. Choose from the durable connector block or standard cable connections.
-
M9133A -
Keysight Technologies
The M9133A is a high-density, general purpose switch with 100 independent, single-pole, single-throw (Form A) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights or actuate external power relays and solenoids. The high-speed, long-life reed relays can handle 100Vrms and 1A, with up to 25W power. Choose from the durable connector block or the standard cable connections.
-
34947A -
Keysight Technologies
The Keysight 34947A microwave switch for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching for test signals from DC to 26.5 GHz. These switches provide excellent insertion loss, isolation, and VSWR specification. The microwave switches are configured as three independent 1x2 (SPDT) unterminated switches on a single module. For general-purpose microwave switching applications, the module can be used to switch separate signal sources for a multi-band receiver/transmitter testing application.
-
784307-01 -
NI
PCI Express, Cabled Switch Device—The CPS‑8910 is designed for large multiple-input, multiple output (MIMO) expansion configurations and system control on the PXI platform or software defined radio devices. The CPS‑8910 provides two PCI Express upstream ports and eight downstream ports for seamless system expansion. You can connect the downstream ports to external devices, such as a Software Defined Radio Reconfigurable Device, to create large multichannel MIMO systems. You also can connect multiple CPS‑8910 switch boxes to a single PXI Express chassis to create massive MIMO systems with a Software Defined Radio Reconfigurable Device. The large data throughput capacity makes the CPS‑8910 an ideal data aggregator for massive MIMO systems. You can use the CPS‑8910 with copper or fiber-optic cables.
-
781420-00 -
NI
4-Slot PXI Carrier Module for SwitchBlock - The PXI‑2800 is a carrier module for SwitchBlock that can hold up to six SwitchBlock relay cards while occupying four PXI slots. By connecting multiple SwitchBlock relay cards through the carrier’s integrated analog bus, you can easily create large matrices with more than 2,000 crosspoints in four PXI slots and more than 8,000 crosspoints in a single PXI chassis.
-
-
34946A -
Keysight Technologies
The Keysight 34946A microwave switch for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching for test signals from DC to 26.5 GHz. These switches provide excellent insertion loss, isolation, and VSWR specification. The microwave switches are configured as two independent 1x2 (SPDT) terminated switches on a single module. For general-purpose microwave switching applications, the module can be used to switch separate signal sources for a multi-band receiver/transmitter testing application.
-
40-792-701 -
Pickering Interfaces Ltd.
The 40-792/793 Daisy Chain Switching Module is designed for telecom test applications. It allows production or verification testing of SONET/SDH transmission multiplexers switching 2MBit/s or 1.5MBit/s data. Traffic is sequentially Daisy- Chained through all tributaries (or any selection of tributaries), modules can be cascaded to test any number of tributaries.
-
782358-01 -
NI
40 GHz, Dual-Transfer PXI Transfer Switch Module—The PXI‑2798 can route RF or microwave signals in automated test applications. Designed to operate with less than 1 dB insertion loss at up to 40 GHz, the PXI‑2798 appears almost invisible to signals at much lower frequencies as well. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2798 is also well-suited for passing high-order harmonics from RF upconverters or routing multiple sources to RF downconverters.